Heating Rate Controller · E5CC-T

Programme Studio

Build a heating programme, then practise entering it using a virtual Omron front panel.
Offline practice only. This builder and virtual keypad cannot control equipment. The graph shows commanded setpoints, not actual heater temperatures. Verify all settings on the physical Omron before use.

Programme

Rate-of-rise method
This is a planning choice, not a controller connection. The physical probe, current C3 configuration and setpoint limits must be verified independently. This planner uses rate-of-rise mode (t-pr = pr, pru = m, t-u = h-m). The controller’s separate step-time method uses different settings and is not generated here. The starting PV is assumed for the graph and cannot be forced by a leading ramp.

Segments

2 / 32

Ramp = SP + whole-number slope (profile units/min). Soak = hold existing SP for a duration. Step = immediate setpoint jump (zero programmed time). To wait for the actual temperature before the next segment, verify controller-wide wt-b is enabled in Adjustment Level. It affects all segments/programmes; this website cannot change it.

Commanded setpoint profile

Omron entry sheet

Builder values live only in this browser. The entry sheet includes the planned in-t and the separate prg RUN selection; no browser action writes to the physical Omron.